User`s guide
Chapter 4: System Operation
XIO Output Specifications
Table 4-7. XIO Output Circuit Specifications
Parameter Value
Power supply voltage range See Specifications for 24 VDC
Power on page 24.
Operational current range, per
channel
I
out
≤ 700 mA
Total Current Limitation, all
channels on.
I
total
≤ 1.0 A @ 50° C ambient
I
total
≤ 1.5 A @ 25° C ambient
ON state resistance (I
out
= 0.5 A)
R
on
≤ 0.32 Ω @ 85° C
Output leakage current I
out
≤ 25 µA
Turn on response time 125 µsec max., 80 µsec typical
(hardware only)
Turn off response time 60 µsec. max., 28 µsec typical
(hardware only)
Output voltage at inductive load
turnoff (I
out
= 0.5A, Load = 1 mH)
(+V - 65) ≤V
demag
≤ (+V - 45)
DC short circuit current limit 0.7A ≤ I
LIM
≤ 2.5 A
Peak short circuit current I
ovpk
≤ 4 A
Adept Cobra ePLC600/800 Robot, User’s Guide, Rev A