User`s guide
Chapter 8 - Maintenance
104 Adept Quattro s650H Robot User’s Guide, Rev A
8. Remove the four hex-head screws holding the Status Display panel.
See the following figure:
Figure 8-5. Status Display Panel, Showing 4 hex-head Screws
9. Remove the Status Display panel.
The battery is supported in a bracket that is attached to the back side of the Status
Display panel with stand-offs. The battery is exposed when the Status Display
panel is removed.
10. The battery bracket assembly has two connectors. Locate the unused battery
connector on the battery bracket. See the following figure:
\
Figure 8-6. Battery Bracket on Status Display Panel
CAUTION: If battery power is removed from the robot,
factory calibration data may be lost, requiring robot
recalibration by Adept personnel.
In-use Battery
Connector
Unused
Battery
Connector
Battery Cable Tie
Status
Display
Panel
Battery
Bracket
Diag Cable