User`s guide
Chapter 3 - SmartController Operation
40 Adept SmartController User’s Guide, Rev. K
Serial Port Configuration
From the Adept ACE software:
1. Double-click on the controller in the tree structure pane.
This opens the object editor for the controller.
2. Select Configure > Configure .
3. Click Configuration.
4. Select SERIAL
5. Click Add, to create a new entry
or
Highlight an entry and click Edit, to modify the existing values.
6. Set the values as appropriate for your port.
7. Click Accept.
8. Click Done.
9. Click Yes, to write the values to the system disk.
10. Click Yes to reboot the controller, so the values you just set will take effect.
Table 3-6. RS-422/485 Connector Pin Assignments
Pin Signal Type
1NC
2RXD+ Input
3TXD+ Output
4TXD- Output
5GND Ground
6RXD– Input
7NC
8NC
9NC