User`s guide

Connecting a Basler 1394b Camera
Adept Peripherals User’s Guide, Rev A 9
2.3 Connecting a Basler 1394b Camera
1. Connect the 1394b cable from the camera to the 1394b port on the SmartVision EX.
2. Connect the 12-pin Hirose cable from the camera to the terminal block.
a. Connect the Hirose pink wire to terminal 41 on the terminal block.
b. Connect the Hirose black wire to terminal 1 (signal 1001) on the terminal block.
3. Connect the terminal block DB50 to the SmartController XDIO port.
4. Connect terminal 2 (signal 1001) to terminal 47 on the terminal block with light gauge
wire (16 - 20 AWG).
Components Used:
Basler 1394b camera
1394b cable
Hirose - unterminated cable, 10 meter
Connects to:
Adept SmartController CX
Adept SmartVision EX (1394b PCIe board)
Options:
DB50 - DB50 Extension Cable (M - F), 5
meter
•Terminal Block
16 - 20 AWG wire, 0.3 meter
DB50 - DB50 Cable (M - F), 2 meter
SmartVision EX
Camera
Basler 1394b Camera
flying
leads
Hirose Cable
(09450-100)
Hirose
Plug
pink lead
to terminal 41
black lead
to terminal 1
wire from terminal
2 to terminal 47
from
Camera
flying
leads
Terminal Block
(09438-000)
1394b Cable
1394b Ports
DB50-DB50
2 m Cable
(09447-020)
DB50 m
DB50 m
DB50 f
Optional DB50-DB50
5 m Extension
(09447-050)
DB50 f
R
ON
SmartServo IEEE-1394
1 2 3 4
SF ES HD
SW1
1.1 1.2 2.1 2.2
OK
123
XDIO
LANHPE
OFF
XSYS
CAMERA
Eth 10/100
XUSR
Device Net
XFP
RS-232/TERM
RS-232-1
XMCP
BELT ENCODER
SmartController CX
-+ -+
RS-422/485
XDC1 XDC2
24V 5A
*S/N 3562-XXXXX*
RS-232-2