User`s guide
Connections
8 Adept Peripherals User’s Guide, Rev A
2.2 Connecting a Basler 1394a Camera
1. Connect the 1394a cable from the camera to the 1394a port on the SmartVision EX.
2. Connect the 10-pin RJ45 cable from the camera to the terminal block.
a. Connect the RJ45 green wire to terminal 41 on the terminal block.
b. Connect the RJ45 white/green wire to terminal 1 (signal 1001) on the terminal block.
3. Connect the terminal block DB50 to the SmartController XDIO port.
4. Connect terminal 2 (signal 1001) to terminal 47 on the terminal block with light gauge
wire (16 - 20 AWG).
C
omponents
U
se
d
:
• Basler 1394a camera
• 1394a cable
• RJ45 10-pin - unterminated cable, 10 meter
Connects to:
• Adept SmartController CX
• Adept SmartVision EX (1394a PCIe board)
O
pt
i
ons:
• DB50 - DB50 Extension Cable (M - F), 5
meter
•Terminal Block
• 16- 20 AWG wire, 0.3 meter
• DB50 - DB50 Cable (M - F), 2 meter
SmartVision EX
Camera
10 1
Basler 1394a Camera
RJ45
CAMERA I/O
09449-010
flying
leads
RJ45 Cable
(09449-100)
green lead
to terminal 41
white/green lead
to terminal 1
wire from terminal
2 to terminal 47
from
Camera
flying
leads
Terminal Block
(09438-000)
1394a cable
1394a Port
DB50 m
DB50-DB50
2 m Cable
(09447-020)
DB50 m
DB50 f
Optional DB50-DB50
5 m Extension
(09447-050)
DB50 f
R
ON
SmartServo IEEE-1394
1 2 3 4
SF ES HD
SW1
1.1 1.2 2.1 2.2
OK
123
XDIO
LANHPE
OFF
XSYS
CAMERA
Eth 10/100
XUSR
Device Net
XFP
RS-232/TERM
RS-232-1
XMCP
BELT ENCODER
SmartController CX
-+ -+
RS-422/485
XDC1 XDC2
24V 5A
*S/N 3562-XXXXX*
RS-232-2
SmartController CX
XDIO Port