User`s guide

PCIe I/O Card Connections
Adept Peripherals User’s Guide, Rev A 23
Typical Input Wiring Example
Figure 4-4. Typical User Wiring for Sinking Input Signals 1009 - 1016
Figure 4-5. Typical User Wiring for Sourcing Input Signals 1009 - 1016
10 - 30 VDC
Supply
+
-
Adept-Supplied Equipment
User-Supplied Equipment
Input 1009
Part Present Sensor
24
Input 1010
Feeder Empty Sensor
23
Input 1011
Part Jammed Sensor
22
Input 1012
Sealant Ready Sensor
21
Input 1013
49
Input 1014
48
Input Comm
47
Wiring
Terminal
Block
Typical User
Input Signals
Note: all Input signals
can be used for either
sinking or sourcing
configurations.
Bank configured for
Sinking (NPN) Inputs
Input Bank
50-Pin Input Connector - I/O Card
(equivalent circuit)
Input 1015
Input 1016
46
2, 3, 4, 28, 29
+
-
10 - 30 VDC
Supply
Adept-Supplied Equipment
User-Supplied Equipment
Input Comm
Input 1009
24
Input 1010
23
Input 1011
22
Input 1012
21
Input 1013
49
Input 1014
48
47
Wiring
Terminal
Block
Note: all Input signals
can be used for either
sinking or sourcing
configurations.
Bank configured for
Sourcing (PNP) Inputs
Input Bank
50-Pin Input Connector – I/O Card
(equivalent circuit)
Input 1015
Input 1016
46
2, 3, 4, 28, 29