User`s guide

Chapter 4: System Operation
Pin No. Designation
Signal
Bank
V+/eV+ Signal
Number
17 Input 5.2 2 1107
18 Input 6.2 2 1108
19 Output 1 0097
20 Output 2 0098
21 Output 3 0099
22 Output 4 0100
23 Output 5 0101
24 Output 6 0102
25 Output 7 0103
26 Output 8 0104
Pin 1Pin 9
Pin 10
Pin 18
Pin 26
Pin 19
Optional I/O Products
These optional products are also available for use with digital I/O:
l
XIO Breakout Cable For information, see XIO Breakout Cable on page 46. This cable is
not compatible with the XIO Termination Block.
l
XIO Termination Block, with terminals for user wiring, plus input and output status
LEDs. Connects to the XIO connector with 6 foot cable. See the Adept XIO Termination
Block Installation Guide for details.
XIO Input Signals
The 12 input channels are arranged in two banks of six. Each bank is electrically isolated from
the other bank and is optically isolated from the robot’s ground. The six inputs within each
bank share a common source/sink line.
The inputs are accessed through direct connection to the XIO connector (see the previous
table), or through the optional XIO Termination Block. See the documentation supplied with
the termination block for details.
The XIO inputs cannot be used for REACTI programming, high-speed interrupts, or vision
triggers.
Adept Cobra s600/s800 Robot, User’s Guide, Rev L