Specifications
Chapter 5 - 030 Processor Module
68 Adept MV Controller User’s Guide, Rev C
5.6 030 Jumper Settings
There are two jumpers on the 030 module that must be set correctly, depending on if it is
used as the main processor or an auxiliary processor. See the table below and Figure 5-3.
Figure 5-3. Switch and Jumper Locations on the 030 Module
a
SCLK (JP3) jumper is ON for the main processor when used
with newer SIO modules – 30330-12350, 30330-11351,
30332-12350, or 30332-12351. All SIO modules manufactured
after 1994 require JP3. It must be OFF when used with older
SIO modules – 30330-00301 or 30330-10351.
Table 5-9. Jumper Settings for 030 Processor Module
Processor Type Jumper Setting
030 #1 used as main processor SCON (JP1) = ON
SCLK (JP3) = ON
a
030 #2-4, used as auxiliary
processor
SCON (JP1) = OFF
SCLK (JP3) = OFF
SCON
JP1
1 2 3 4 5 6 7 8
Adept 030 Board – Component Side
ON
SW2
SCLK
JP3
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com