Specifications

Memory
Adept MV Controller User’s Guide, Rev C 67
5.4 Memory
The 030 system processor can be ordered with 2, 4, or 8 MB of DRAM. Contact Adept
Customer Service for information regarding memory upgrade options for 2 MB and 4 MB
processors.
5.5 VMEbus Address
Each processor module in an Adept MV controller must have a unique module address.
The address is set on switch SW2 on the 030 PC board. Table 5-8 shows the switch settings
for multiple processor modules. See Figure 5-3 for the location of SW2.
If you are using both 040 and 030 processor modules, each module must have a unique
address. You cannot set an 040 and an 030 to the same address. For example, if you have
an 040 and an 030 installed, one of them must be set as module #1 and the other as module
#2. See section 5.7 for additional information.
a
The position notation on DIP switches can vary. If the switch is marked
open/closed, then open = off and closed = on.
Table 5-8. Address Settings for the 030 Processor Module
Module
Number
SW2 Switch Position
a
12345678
1 (main proc) Off on on on on on on on
2 (auxiliary)OffonononononOffon
3 (auxiliary)OffononononOffonon
4 (auxiliary)OffononononOffOffon