Specifications

Serial I/O Connections, 030 Module
Adept MV Controller User’s Guide, Rev C 61
5.3 Serial I/O Connections, 030 Module
RS-422/485 Connector (on 030 Module)
The RS-422/485 connector is a DE-9F 9-pin female connector. The pin assignments and
locations are shown below. RS-422 is a point-to-point protocol for connection to a single
destination. This port can also be configured as a “multi-drop” port (RS-485).
To change the configuration use the
CONFIG_C
utility program or the V
+
FSET
program
instruction. This port is designated
LOCAL.SERIAL:1
.
Figure 5-1. RS-422/485 Female Connector Pin Locations (on 030 module)
Table 5-1. RS-422/485 Connector Pin Assignments
Pin Signal Pin Signal
1RTS+ 6RTS
2RXD+ 7RXD
3TXD+ 8TXD
4CTS+ 9CTS
5Ground
Pin 5
Pin 1
Pin 9
Pin 6
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com