Specifications
Installing a Stand-Alone Controller in a Rack or Panel
Adept MV Controller User’s Guide, Rev C 37
5. Set the baud rate to 9600, that is the default rate for the Adept system. To change
the baud rate, refer to the information on
CONFIG_C
in the Instructions for Adept
Utility Programs.
3.10 Installing a Stand-Alone Controller in a Rack or Panel
An MV-5 or MV-10 Stand-Alone controller can be mounted in a standard 19-inch
equipment rack using the attached mounting brackets. The brackets can also be moved to
the rear of the controller for panel mounting.
NOTE:
To maintain compliance with EN 60204-1, the mounting of the
controller and all terminations at the controller must be performed in
accordance with this standard.
Space Around the Chassis
When the Stand-Alone controller is installed, you must allow 25 mm (1 inch) at the left
and right sides of the chassis for proper air cooling. You must also allow 75 mm (3 inches)
at the front of the chassis for power and signal cable clearance.
CAUTION:
The air filter must be kept clean so the forced air cooling
system can work efficiently. See Chapter 14 for details on cleaning the
filter.
Rack Mounting
To rack mount the Adept MV-5 or MV-10 Stand-Alone controller in a standard 19-inch
equipment rack, you must use the mounting brackets from the accessories kit. See
Figure 3-8 for instructions. See Appendix A for dimensions.
Figure 3-8. Rack Mounting for MV-5/MV-10 Stand-Alone Controller
!
Front
Side View of MV-5 or MV-10
To install mounting brackets in rack mount
position:
• Remove 4 existing screws and washers
from side of chassis at locations shown
in drawing.
• Place bracket in position and secure
with same screws and washers removed
above.
• Repeat process for other side of controller.