Specifications
Chapter 3 - Installation for MV-5 and MV-10 Controllers
36 Adept MV Controller User’s Guide, Rev C
3.9 Installing a Terminal in an S-Series System
With an S-Series Adept MV controller system, the customer must supply the terminal and
cable to interface to the controller. The terminal must be a Wyse Model 60 or 75 with an
ANSI
keyboard, or a compatible terminal. You may also be able to use a computer with
suitable terminal emulation software. For DOS or Windows-compatible computers, the
programs “ProComm+” or “ProComm for Windows” (available from many computer
stores) include software emulation for the Wyse-75.
Recommended Terminal for S-Series Systems
The recommended terminal for use with the Adept MV controller is the Wyse WY-60. You
must also specify that you require the Wyse ANSI/VT100 style keyboard (Wyse p/n
900127-02 or 900128-02). Note: The WY-60 is also available with ASCII and IBM Enhanced
PC keyboards. These are NOT Adept-compatible. You must make sure you order the
correct keyboard. The WY-60 is available in both 220V and 110V configurations,
depending mainly on the country you buy it in.
Contacting WYSE
Wyse Technology, 3571 N. First St., San Jose, CA 95134, USA
Tel: USA: 1-800-GET-WYSE. Northern Calif.: (408) 473-1600
International (partial list): GERMANY (0894)-600990, FRANCE (1) 69-82-91-00,
UK (01734)-342200, TAIWAN(238)-81306, SINGAPORE 254-5860.
All others, call USA (408) 473-1800
(Phone numbers correct as of July 1994. Source: Wyse USA)
Customer-Supplied Serial Interface Cable
A Wyse WY-60 terminal has a 25-pin female D subminiature connector (DB-25F), which
requires a 25-pin male connector (DB-25M) on the interface cable. The 030 module
RS-232/Term connector is a 9-pin male connector (DE-9P) which requires a 9-pin female
connector (DE-9F). See section 5.3 for details on connecting a Wyse terminal to an 030
module. See section 6.3 for information on connecting the 040 module to a Wyse terminal.
If you are using a terminal other than a Wyse WY-60, check the documentation on the
serial connector before you purchase or build the serial interface cable.
Installation Procedure
1. Make sure the controller is turned off before making any connections.
2. Verify the voltage range marked on the terminal is compatible with your local
voltage source. Connect the AC power cord to the terminal, then plug it into an
appropriate voltage source.
3. Connect a suitable serial cable between the terminal and the RS-232/Term
connector on the System Processor module.
4. If the terminal is a Wyse 60, use the setup mode to set the personality to
“WY-75”. If you are using terminal emulation software on a computer, set the
software to “WY-75” emulation. If “WY-75” is not available, try “VT102” or
“VT100”, but you will not be able to use all of the function keys.