Specifications
Fan and Filter Information
Adept MV Controller User’s Guide, Rev C 29
NOTE: The “T” suffix indicates the fuse response time - a 5 AT fuse rating
specifies a 5 amp “slow blow” type.
Figure 3-4. MV-5/MV-10 Fuse Holder
3.6 Fan and Filter Information
Cooling Fan
The chassis is cooled by an internal fan in the chassis. On a robot controller, the air intake
is through the bottom of the chassis and the exhaust is out through the top. On a
stand-alone controller, the air intake is through the right side of the chassis and the
exhaust is out through the left side.
Filter Inspection and Cleaning
The fan filter must be inspected at least once per month to check for dirt and dust buildup.
The fan filter is located behind the filter cover on the front of the controller (see
Figure 3-1). See Chapter 14 for information on inspecting and cleaning the fan filter.
Table 3-4. MV-5 and MV-10
Fuse Ratings
Fuse Rating Type
F1 – AC Line fuse at Power
Entry module
5 AT/250 V IEC 127-style
5 x 20 mm
F2 – AC Line fuse at Power
Entry module
5 AT/250 V IEC 127-style
5 x 20 mm
USE ONLY WITH
250V FUSES
Fuse Holder
Side view of
Fuse Holder
Fuses
F1 and
F2
Spare fuses
in sliding
compartment