Specifications

Appendix E - System Messages
Adept MV Controller User’s Guide, Rev C 213
*File format error* (–512)
Explanation: The requested disk file is not in a format acceptable to V
+
because either it
was not created by V
+
or the file has been corrupted.
User action: Use another diskette or reference another file.
*File or subdirectory name error* (–514)
Explanation: The specified file name or subdirectory was not a valid disk file name, the
directory path contained invalid syntax, or the directory path was too
long.
User action: Retry the operation with a correct file name or subdirectory name. Verify
that syntax of the directory path is correct. Check that any default
directory path specified by the DEFAULT command is correct. Check that
the total directory path is not too long when the default is combined with
the current file specification.
*Graphics processor timeout* (–552)
Explanation: The graphics processor (on the system processor) failed to respond to a
command from V
+
within five seconds.
User action: Save all your programs and variables on disk and then reboot the system
from disk. Contact Adept Customer Service if the problem repeats.
*Graphics software checksum error* (–558)
Explanation: The code on the graphics board has been corrupted.
User action: Save new or modified programs, restart the controller, reload the
programs. If the problem persists, contact Adept customer service.
*Graphics storage area format error* (–555)
Explanation: During execution of a FREE command, V
+
has detected that the
information in graphic memory may have been corrupted. This may have
been caused by a momentary hardware failure or a software error.
User action: Attempt to save as much as possible onto disk. Issue ZERO 1 and ZERO 2
monitor commands to delete graphics data. If the error persists, power
down the controller and restart the system.
(HALTED) (8)
Explanation: A HALT instruction (in the application program) has been executed, and
thus execution of the current program has terminated.
User action: Any monitor command can be entered, but PROCEED cannot be used to
resume program execution.
*Hard envelope error* Mtr n (–1027)
Explanation: The indicated motor was not tracking the commanded position with
sufficient accuracy, indicating a failure in the hardware servo system or
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com