Specifications
Appendix C - Additional Standards Compliance Information
176 Adept MV Controller User’s Guide, Rev C
C.3 Electromagnetic Compatibility Testing Results
The Adept MV controller family meets all applicable requirements as mandated by the
European Union (EU) EMC Directive. Table C-2 summarizes the test results of some of the
most critical tests.
Table C-2. EMC Test Results
Test Performed Status
Fast Transient Burst (FTB)
EN61000-4-4 to level 3
(2 kV power, 1 kV I/O)
Passed without qualification
Electrostatic Discharge (ESD)
IEC61000-4-2 to level 4
(8 kV contact discharge)
Passed without qualification
Radiated Immunity
ENV50140 to level 3
(10 V/m; 80-100 MHz, 80% mod. @ 1 kHz)
Passed without qualification
Conducted Immunity
ENV50141 to level 3
(10 V)
Passed without qualification
Damped Oscillatory
IEC255-4
(1 kV)
Passed without qualification
Gradual Shutdown and Start-up
IEC1131-2
Passed without qualification
Surge
EN1000-4-5 to level 3
2 kV common mode on I/Os only
Passed without qualification
Radiated Emissions
EN55011 for group 1 ISM to Class A - 2 dB
Passed without qualification
Conducted Emissions
EN55011 for group 1 ISM to Class A - 2 dB
Passed without qualification
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com