Specifications

IEC Test Information
Adept MV Controller User’s Guide, Rev C 175
C.2 IEC Test Information
The Adept MV controller has passed the following IEC 1131 test conditions:
Voltage drops, normal service: Severity level PS2
Relative Humidity: Severity level RH2
ESD (Electro-Static Discharge): Severity level 4*
*The Adept MV controller was tested at severity level 4 for ESD. In order to maintain
compliance, Adept advises the use of proper EMC suppression techniques. All cables
between the controller and peripheral equipment, including the power chassis in an
Adept robot system, should be shielded and properly grounded at both termination
points. Where the use of unshielded cables cannot be avoided, additional EMC
suppression measures, such as the use of twisted pair, ferrite inductors, or band pass
filters, should be employed.
Every MV controller is 100% tested to ensure Ground Continuity of less than 0.1¾ at 30A.
NOTE:
More information on Input/Output performance characteristics
for applicable modules in the MV controller is available on request from
Adept. Please contact Customer Service for a copy.