Specifications
VFP Lamp Test
Adept MV Controller User’s Guide, Rev C 159
14.4 VFP Lamp Test
You should perform this test at least every six months to verify all lamps are working.
With the controller turned on, press the Lamp Test button on the VFP. If any of the lamps
do not light, especially the High Power and Program Running lamps, contact Adept
Customer Service.
14.5 Spare Parts List MV-8/MV-19
Part numbers and specifications are subject to change. Contact Adept Customer Service
for ordering information for items in Table 14-1, or for items not listed.
a
These items are not available from Adept.
Table 14-1. Spare Parts From Adept
Description
Adept Part
Number
Quantity General Comments
Fan Filter 40330-11190 MV-8 =1
MV-19=2
Front Panel Bypass plug 10330-01040 1 User can build own, see Figure 7-5.
E-stop test plug, for I/O port
on SIO module
10330-01075
1
Fuse holder, metric
(5mm x 20 mm)
27400-00350
5
These items installed in every
controller when shipped.
Alternate fuse holder
(1/4" x 1 1/4")
27400-00360
5
These items included in accessory
kit.
Table 14-2. Spare Parts From Third Parties
a
Description Specification Quantity General Comments
Fuse F1 and F2 (same value) –
for 200-240VAC
1AT/250V, 5x20mm,
IEC 127 style
2
If 5x20mm fuses are
not readily available,
install alternative
fuse holders from
accessory kit, and use
3AG (1/4" x 1 1/4")
fuses instead.
Fuse F1 and F2 (same value) –
for 100-120VAC
2AT/250V, 5x20mm,
IEC 127 style
2
Fuse F3 and F4 (same value)
for 200-240VAC
MV-8
MV-19
IEC 127 style:
2.5AF/250V, 5x20mm
6.3AF/250V, 5x20mm
2
Fuse F3 and F4 (same value)
for 100-120VAC
MV-8
MV-19
IEC 127 style:
5AF/250V, 5x20mm
8AF/250V, 5x20mm
2
Fuse F5 0.5AF/250V, 5x20mm,
IEC 127 style
1
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com