Specifications
Chapter 14 - Maintenance
158 Adept MV Controller User’s Guide, Rev C
14.1 Introduction
NOTE:
The Adept MV Controller has no user-serviceable parts other than
the items mentioned in this chapter.
WARNING:
The procedures and replacement of parts mentioned in this
section should only be performed by skilled or instructed persons, as
defined in section 1.3 on page 4.
14.2 Fan Filter Inspection and Cleaning MV-8/MV-19
The air filter located on the front of the chassis should be inspected regularly and cleaned
at the first sign of dust or dirt buildup. The filter must be inspected and cleaned at least
once per month. Regular cleaning will prolong the life of the filter. If the filter becomes
clogged or unusable for any reason, you will need to order a new air filter; the Adept part
number is 40330-11190.
CAUTION:
If the fan stops working or the filter becomes dirty, the
controller could overheat and cause a thermal failure. This applies to all
models of MV controllers.
1. Turn off the controller.
2. Open the front grill by loosening two screws and swinging the grill out.
3. Pull the air filter out and inspect for dust or dirt particles. If cleaning is required,
use compressed air to clean the filter. (Follow appropriate safety procedures
regarding use of compressed air.)
4. Replace the cleaned air filter and secure the grill.
14.3 Fan Filter Inspection and Cleaning MV-5/MV-10
The air filter located on the front of the chassis should be inspected regularly and cleaned
at the first sign of dust or dirt buildup. The filter must be inspected and cleaned at least
once per month. Regular cleaning will prolong the life of the filter. If the filter becomes
clogged or unusable for any reason, you will need to order a new air filter; the Adept part
number is 40340-00030.
1. Turn off the controller.
2. Loosen the two screws on the fan filter cover to gain access to the filter, see
Figure 3-1 on page 25.
3. Pull the air filter out and inspect for dust or dirt particles. If cleaning is required,
use compressed air to clean the filter. (Follow appropriate safety procedures
regarding use of compressed air.)
4. Replace the cleaned air filter and secure the filter holder.
!