Specifications

Additional DIO Modules
Adept MV Controller User’s Guide, Rev C 153
13.7 Additional DIO Modules
Setting the Module Address
Additional DIO modules can be installed in an Adept MV controller, up to a maximum of
8 modules per controller, depending on slot availability. The total digital I/O channels
available, including the channels on the SIO modules are:
maximum digital input channels = 268
maximum digital output channels = 264
Each module that is added must have a unique VMEbus address so the controller can
recognize it properly. The address is set at DIP switch S1 on the DIO PC board. The switch
settings are shown below. See Figure 13-3 for the location of S1.
Labeling Sets of Cables
The optional Adept input and output cables for the DIO modules are the same for each
additional module you that add to a controller. Make sure to clearly label each set of four
cables so that they are identified with a specific DIO module. Also see the warning on
page 148 about swapping the two input cables or the two output cables with each other.
Table 13-8. Switch Settings for S1 on DIO Module
8-Position DIP Switch S1 on DIO PC board
Switch positions 1 to 6 – to select bus address for DIO modules
DIO
Module
Number
Input
Signals
Output
Signals
Switch position
654321
1 1033 – 1064 33 – 64 closed closed closed closed closed closed
2 1065 – 1096 65 – 96 closed closed closed closed closed
Open
3 1097 – 1128 97 – 128 closed closed closed closed
Open
closed
4 1129 – 1160 129 – 160 closed closed closed closed
Open Open
5 1161 – 1192 161 – 192 closed closed closed
Open
closed closed
6 1193 – 1224 193 – 224 closed closed closed
Open
closed
Open
7 1225 – 1256 225 – 256 closed closed closed
Open Open
closed
8 1257 – 1288 257 – 288 closed closed closed
Open Open Open
Switch position 7
– required setting is closed
Switch position 8
– required setting is open