Specifications
VMEbus Address and Configuration
Adept MV Controller User’s Guide, Rev C 111
9.3 VMEbus Address and Configuration
The VIS module will be configured as module 1, unless the system is running the Dual
AdeptVision option, in which case, the second VIS module will be module 2. If you have
only one VIS module installed, it will be set correctly when the controller is shipped to
you.
If you install a new VIS module (as a replacement part or upgrade) or have the Dual
Vision option, see the tables below for the address switch settings. The shaded cells
indicate the settings that are different for each board. See Figure 9-1 for the position of the
A and B settings. See Figure 9-2 for the location of SW1, SW3, and SW2 on the VIS module.
Figure 9-1. Switch Positions A and B in Relation to Arrows on SW1, SW3, and SW2
SW1-3 (3rd switch on SW1) selects either:
• B: POS_LATCH 1 and VIS_TRIGGER 1 (recommended for VIS module 1)
or...
• A: POS_LATCH 2 and VIS_TRIGGER 2 (recommended for VIS module 2)
All other switches on SW1, SW3, and SW2 should be set as shown above.
Table 9-1. Switch Settings for VIS Module 1
12345678
SW1 A B
BB
SW3AABBBB
BB
SW2AAA
BAAAA
Table 9-2. Switch Settings for VIS Module 2
12345678
SW1 A B
AB
SW3AABBBB
AB
SW2AAA
AABAA
AB