Setup guide

VISTA-32FB Installation and Setup Guide
6-10
Time-Driven Event Programming
The following menu items must first be programmed in Output Programming in the #93 Menu Mode:
Enter Relay No. (reference identification number)
Output Group (if applicable)
Restriction
Output Type (V-Plex, 4204/4204CF)
Zone No. (V-Plex)
ECP Address (4204/4204CF)
Relay No. (4204/4204CF)
After entering Scheduling Menu Mode, press [0] until the “Timed Events ?” prompt appears.
PROMPT
EXPLANATION
Timed Events ?
1 = YES 0 = NO 0
Enter 1 to program timed events.
TIMED EVENT # ?
01-20, 00=Quit 01
Enter the timed event number to be programmed (01-20).
Press [].
The system then prompts the user to enter the desired action to be taken.
Enter 00 at the TIMED EVENT #? prompt to quit the timed event menus and display the Quit ? prompt.
01 ACTION ?
none 00
Enter the action code for this timed-event number from the list at the left. This could be an output command,
an arming command, or any other Time-Driven event.
Press [] to accept the entry. The prompt for the action specifier appears.
ACTION CODES EXPLANATION ACTION SPECIFIER
01=Relay On
02=Relay Off
03=Relay Close for 2 seconds
04=Relay Close XX minutes
05=Relay Close YY seconds
Actions 01-05
If you selected actions 01-05, the prompt at the right appears. Enter the relay
number.
Press [] to accept entry. The Time Window ? prompt appears.
01 RELAY # ?
00
06=Relay Group On
07=Relay Group Off
08=Relay Group Close for 2
seconds
09=Relay Group Close XX
minutes
10=Relay Group Close YY
seconds
Actions 06-10
If you selected actions 06-10, the prompt at the right appears. Enter the relay
group number.
Press [] to accept entry. The Time Window ? prompt appears.
01 RELAY GRP # ?
00
20=Arm-STAY
21=Arm AWAY
22=Disarm
23=Force Arm STAY
24=Force Arm AWAY
40=Enable Open Window by
Part.
41=Enable Close Window by
Part.
Actions 21-26 and 40-41
If you selected actions 21-24 or 40-41, the prompt at the right appears. Enter
the partition to which the action applies. Enter 0 to select all partitions. Enter
a partition number again to deselect it.
Press [] to accept entry. The Time Window ? prompt appears.
PART? 1 2
HIT 0-2 X X
30=Auto bypass Zone list
31=Auto unbypass Zone list
Actions 30-31
If you selected actions 30-31, the prompt at the right appears. Enter the zone
list number that contains the zones to be bypassed or unbypassed.
Press [] to accept entry. The Time Window ? prompt appears.
01 ZONE LIST ?
ENTER 01-15 01
42=Enable Access Window for
Access group(s)
Action 42
If you selected action 42, the prompt at the right appears. Enter the group
number to which the time window will apply.
Press [] to accept entry. The Time Window ? prompt appears.
GROUP ? 12345678
HIT 0-8 X