Setup guide

Section 6 – Scheduling Options
6-9
Relay Commands
Action Code Action Action Specifier
01 Relay On Relay #
02 Relay Off Relay #
03 Relay Close for 2 seconds Relay #
04 Relay Close XX minutes (set in field 1*74) Relay #
05 Relay Close YY seconds (set in field 1*75) Relay #
06 Relay Group On Relay Group #
07 Relay Group Off Relay Group #
08 Relay Group Close for 2 seconds Relay Group #
09 Relay Group Close XX minutes (set in field 1*74) Relay Group #
10 Relay Group Close YY seconds (set in field 1*75) Relay Group #
Arm/Disarm Commands
Action Code Action Action Specifier
20 Arm-STAY Partition(s)
21 Arm AWAY Partition(s)
22 Disarm Partition(s)
23 Force Arm STAY (Auto-bypass faulted zns) Partition(s)
24 Force Arm AWAY (Auto-bypass faulted zns) Partition(s)
The auto-arm warning (field 2*06) applies when using Time-Driven events to auto-arm.
Temporary schedules do not override an auto-arming or auto-disarming programmed in Time-Driven events.
The auto-arming window cannot be extended using the Installer Code + #82 Mode.
Bypass Commands
Action Code Action Action Specifier
30 Auto bypass Zone list Zone list #
31 Auto unbypass Zone list Zone list #
Open/Close Windows
Action Code Action Action Specifier
40 Enable Opening Window by partition Partition(s)
41 Enable Closing Window by partition Partition(s)
42 Enable Access Window for access group Access Group
50
Off-Normal Reminder (starts local keypad beeping if
fire or system trouble condition exists)
None
Access Control Commands 55 – 78 Not Used
3. Enter the desired activation time (when the action is to take place). Select from:
Activation Time Description
1 Beginning of time window.
2 End of time window.
3
During time window active period only (on at beginning of window, off at end).
For example, if bypass is selected to activate during the window, zones in a zone list are bypassed at the beginning
of the window and unbypassed at the end of the window.
4
Beginning and end of time window (e.g., a coffee break buzzer). In this example, if relay pulse is selected, the relay
pulses for 2 seconds at the beginning of the window, signaling the beginning of the coffee break. At the end of the
window it pulses again, signaling the end of coffee break.