Setup guide

Section 5 – Data Field Descriptions
5-15
FIELD
TITLE and DATA ENTRIES EXPLANATION
3
310
Backup Dialer TouchTone or
Rotary
0 = rotary
1 = touchtone
Select the dialing method for the backup dialer.
3*50
Zone Type Restore Enables for
Types 16-18
0 = disable
1 = enable
This field has three entries, one for each zone type. Select the zone types that
will send Restore reports.
Must be 1 for UL commercial fire and burglary installations
3
550
Second OFF for Bell 1
0 = disable
1 = enable
If enabled, the system silences bell 1 output when the second User Code +
OFF Code is entered after a fire alarm. If disabled, the system silences bell 1
output after the first User Code + OFF.
3
560
Second OFF for Bell 2
0 = disable
1 = enable
If enabled, the system silences bell 2 output when the second User Code +
OFF Code is entered after a fire alarm. If disabled, the system silences bell 2
output after the first User Code + OFF.
3
570
Confirmation of Arming Ding Bell
2 & Auxiliary Relay
0 = disable
1 = enable
This field has two entries, one for bell 2 and one for the auxiliary relay. If
enabled, produces ½-second external alarm sounding (ding) at the end of
exit delay (or after kissoff from the central station, if sending closing reports).
NOTE: If using a keyfob, when the button is pressed, either for arming or
disarming, the bell will ding indicating that the button is working.
Must be 1 for Commercial Burglary installations.
3
590
Enable Bell 2 & Auxiliary Relay
Chime Annunciation
0 = disable
1 = enable
This field has two entries, one for bell 2 and one for the auxiliary relay. If
enabled, the system produces chime annunciation on the output.
NOTE: Must be set to 0 if Bell 2 or Aux. Relay is used for Fire.
3
600
Bell 2 & Auxiliary Relay Timeout
Enter 01-15 multiplied by 2 minutes.
00 = no timeout.
This field has two entries, one for bell 2 and one for the auxiliary relay.
Defines the length of time the output and the keypads sounder will sound for
all audible alarms.
Must be a minimum of 16 minutes for Commercial bBrglary installations and a
minimum 6 minutes for Commercial Fire installations.
3
610
Auxiliary Relay Function
Selection
0 = trouble/supervisory
1 = alarm, silenced by User Code + OFF
2 = smoke detector reset
3 = battery save
4 = alarm, silenced by User Code + # + 67
Select the condition that will trigger the auxiliary relay.
NOTES:
Select “4” for applications requiring independent resetting of the relay.
Smoke detector reset triggers the relay momentarily (approximately 6
seconds) on the second User Code + OFF entry.
Battery save is used to disconnect power from non-critical loads 4 hours after
AC loss.
3
820
Burglary Features on Partition 1
Enable
0 = disable
1 = enable
If enabled, arming, test and chime modes can be used on partition 1.
NOTES:
These features are automatically enabled on all other partitions.
Must be set to 0 in Commercial Fire installations.
3
850
System Zone Bypass Inhibit
0 = prevent bypass
1 = allow only installer to bypass
2 = allow only installer and master codes to
bypass
Select which codes, if any, that can bypass fire zones and systems zones.
NOTES:
This applies to fire zones programmed with zone types 9, 16, 17, and 18 and
system zones 970-977.
The bypassing can only be done from partition 1.