Setup guide
VISTA-32FB Installation and Setup Guide
5-12
FIELD
TITLE and DATA ENTRIES EXPLANATION
2
✴
✴✴
✴
020
Daylight Saving Time Start/End
Weekend
0 = disable
1 = enable
Enter the start and end weekends for daylight saving time as follows: 1=first;
2=second; 3=third; 4=fourth; 5=last; 6=next to last; 7=third from last.
Standard setting for U.S. is 2, 1.
2
✴
✴✴
✴
050
Auto-Arm Delay (partition-
specific)
00 = no delay.
01-14 times 4 minutes (04-56) delay.
15 = no auto arming.
This is the time between the end of the arming window and the start of auto-
arm warning time (field 2*06).
NOTE: This field must be set to “00” for UL installations.
2
✴
✴✴
✴
060
Auto-Arm Warning Period
(partition-specific)
01-15 times 1-minute warning.
00 = no warning period.
This is the time that the user is warned by a keypad sounding and display to
exit the premises prior to auto arming of the system.
NOTE: This field must be set to “00” for UL installations.
2
✴
✴✴
✴
070
Auto-Disarm Delay (partition-
specific)
00 = no delay.
01-14 times 4 minutes (04-56) delay.
15 = no auto disarming.
This is the time between the end of the disarming window and the start of auto
disarming of the system.
NOTE: This field must be set to “15” for UL for UL864 compliance.
2
✴
✴✴
✴
080
Force Arm Enable for Auto-Arm
(partition-specific)
0 = disable
1 = enable
If enabled, the system automatically bypasses any faulted zones when it
attempts to auto-arm.
If disabled, the system will not auto-arm.
NOTE: This field must be set to “0” for UL installations.
2
✴
✴✴
✴
090
Open/Close Reports by
Exception (partition-specific)
0 = disable
1 = enable
If enabled, Open/Close reports are sent only if the openings/closings occur
outside the arm and disarm windows.
NOTES:
Open reports are also suppressed during the closing window in order to
prevent false alarms if the user arms the system, then re-enters the premises,
for example to retrieve a forgotten item.
Openings and closings are still recorded in the event log.
This field must be set to 1 if No Opening and No Closing reports are to be
sent.
2
✴
✴✴
✴
100
Allow Disarming Only During
Arm/Disarm Windows (partition-
specific)
0 = disable
1 = enable
If enabled, disarming of the system is allowed only during the
arming/disarming windows, or if the system is in alarm (if 2*11 is set to 1).
NOTE: This applies only to Operator-level users. Installer, Master, and
Manager-level users can disarm the system at any time.
2
✴
✴✴
✴
110
Allow Disarm Outside Window if
Alarm Occurs
0 = disable
1 = enable
If enabled, allows the system to be disarmed outside the programmed disarm
(opening) window if an alarm has occurred. Otherwise disarming is allowed
only during the disarm window.
NOTE: Used only if field 2*10 is enabled.
2
✴
✴✴
✴
180
Enable GOTO for this Partition
(partition-specific)
0 = disable
1 = enable
If enabled, this partition can be accessed from another partition’s keypad
using the GOTO command.
NOTE: Must be disabled “0” for partition 1 in Commercial Fire installations.
2
✴
✴✴
✴
190
Use Partition Descriptor
0 = disable
1 = enable
If enabled, the normal keypad display will include a partition number and four-
digit descriptor.
2
✴
✴✴
✴
200
Enable J2 Triggers for Partition
(partition-specific)
0 = disable
1 = enable
If enabled, the J2 triggers function for this partition.