Setup guide
VISTA-32FB Installation and Setup Guide
5-10
FIELD
TITLE and DATA ENTRIES EXPLANATION
1
✴
✴✴
✴
350
Access Control Dialer Enables
0 = disable
1 = enable
There are six entries for this field as follows: Trace, Trouble, Not Used,
Bypass, System, and Alarm.
If Trace is enabled, access grant/denial events sent to the central station.
For the other events, if enabled, a report is sent to the central station.
Not Used.
1
✴
✴✴
✴
420
Call Waiting Defeat
0 = disable
1 = enable
If enabled, the system defeats Call Waiting on the first outgoing call attempt to
both the primary and secondary numbers.
NOTES:
After the panel's initial call to report the alarm, the panel may attempt to make
an additional call, perhaps for a cancel or a zone restoral. If Call Waiting is
not defeated, an operator at the central station attempting to contact the
premises (to verify whether the alarm is valid) hears the phone ringing
indefinitely and must to dispatch on the call.
DO NOT enable this feature unless Call Waiting is being used.
1
✴
✴✴
✴
430
Permanent Keypad Display
Backlighting (partition-specific)
0 = disable
1 = enable
If enabled, backlighting for the keypad display remains on at all times.
Otherwise the backlighting comes on when a key is pressed.
NOTE: When a key is pressed, display backlighting turns on for all keypads in
that partition.
1
✴
✴✴
✴
440
Wireless Keypad Tamper Detect
0 = disable
1 = enable
If enabled, when more than 40 key depressions are received without a valid
sequence (arm, disarm, etc.), the control panel disables the wireless keypad.
The inhibit is removed once a valid key sequence is received from a wired
keypad.
Not Used. Must be disabled (“0”).
1
✴
✴✴
✴
450
Exit Delay Sounding (partition-
specific)
0 = disable
1 = enable
If enabled, the system produces slow beeping from the keypads during exit
delay and reverts to rapid beeping during the last 10 seconds of the exit delay.
NOTES:
The duration of the beeping is the programmed value of field *10 regardless of
which entry/exit zone is used to exit the premises.
See page 32 in the Programming Guide, “SOUND OPTION”, prompt for
disabling the entry/exit beeps on the individual keypads.
1
✴
✴✴
✴
470
Chime on Bell 1 (partition-
specific)
0 = disable
1 = enable
If enabled, the system produces chime annunciation on the Bell 1 output.
1
✴
✴✴
✴
480
Wireless Keypad Assignment
0 = none
1-2 = partition number
Select the partition in which RF keypad is used.
Not Used. Must be disabled (“0”).
1
✴
✴✴
✴
490
Suppress Transmitter
Supervision Sound
0 = disable
1 = enable
If enabled, no trouble soundings occur on the keypad for transmitter check-in
failures.
Must be 0 for UL installations.
1
✴
✴✴
✴
520
Send Cancel If Alarm + Off
(partition-specific)
0 = disable
1 = enable
If enabled, Cancel reports are sent when the system is disarmed after an
alarm, regardless of how much time has gone by.
If disabled, Cancel reports are sent within Bell Timeout period only.
NOTE: This option must be enabled so Cancel reports are always sent.
1
✴
✴✴
✴
530
Disable Download Callback
0 = callback required
1 = no callback required
Select whether a callback from the control panel is required for downloading.
Must be 0 for commercial fire and burglary installations.
1*55
European Date Format
0 = disable (mm/dd/yy)
1 = enable (dd/mm/yy)
Select the date format for display in the event log.