Setup guide
VISTA-32FB Installation and Setup Guide
4-8
Using the a Relay to Unlock A Door
This control can be programmed so that a user can
trigger a relay for 2 seconds (e.g., to unlock a door) by
entering the User Code + [ 0 ].
To program a relay for this purpose, perform the
following steps::
Step Action
1 Enter Output Programming in the #93 Menu
Mode.
Step Action
2 Program the output type as 1, or 2.
3 For type 1, program the ECP address and
relay number.
4 For type 2, program the house and unit codes.
5
Program the relay number in field 1∗76
(partition-specific).
See Output Programming in the Programming Guide
for a detailed explanation.
Programming for ECP Communications Device
• Program the Communications Device in Device
Programming in the #93 Menu Mode Programming.
• Program field ✳56: Selects the time the panel
should wait before it attempts to send a message to
the second destination..
• Program field ✳57: Selects the initial reporting
destination for messages.
• Program field ✳58: Selects events for the primary
sub’s ID
• Program field ✳59: Selects events for the secondary
sub’s ID.
Programming for the Event Log
• Program field 1✳70 Event Log Types (1=enable;
0=disable for each type)
• Program field 1✳71 12/24-Hour Time Stamp
Format (0=12 hr; 1=24 hr)
• Program field 1✳72 Event Log Printer On-line
(0=disable; 1=enable)
• Program field 1✳73 Printer Baud Rate (1=300;
0=1200)