Following is a list of commands used while in the Menu Mode:
#93 Menu Mode Programming Commands
#93
Enters Menu Mode.
[]
Serves as [ENTER] key. Press to have keypad accept entry.
[#]
Backs up to previous screen.
0
Press to answer NO.
1
Press to answer YES.
00, or 000+[]
Quits Menu Mode and goes back to Data Field Programming Mode, if entered at first prompt of each main menu option.
Zone Number Designations
The VISTA-32FB supports up to 32 zones of hardwire,
polling loop and/or wireless protection, distributed
between two partitions. The following table lists the
zone numbers and the types of sensors that can be used
with each, and some alternate functions of the zones.
Zone
Function
001 &
002
2-wire Smoke Detectors (if used)
005 Audio Alarm Verification (if used)
006 Cabinet Tamper/Ground Fault (if used)
007 Keyswitch (if used)
008 Latching-Type Glassbreak Detectors (if used)
001-032 Traditional Hardwired Zones
001-032 5800 Series Wireless Devices
010-032 Polling Loop Devices
995 + 1 Panic (Do not use in Fire Alarm applications)
996 # + 3 Panic (Do not use in Fire Alarm applications)
999 + # Panic (Do not use in Fire Alarm applications)
Zone Defaults
Zone # Zone Type Zone # Zone Type
001 09 800-830 00
002 09 970 19
003 03 971-974 19
004 03 975 00
005 03 988 & 990 00
006 03 992 N/A
007 03 995 00
008 03 996 00
010032 00 997 19
601-632 00 999 06
NOTE: Zone 992 is the Duress zone. Programming of
the zone response type is not applicable. This zone does
not require a zone type, only the report code
programming.
Zone Index
The zones are designated as follows:
ZONE #
RANGE
ZONE
FUNCTION
ACTUAL ZONE
001 032 Protection
zones
As indicated
601 632 Relay
Supervisory
Zones
6 + 2-digit Relay Number; e.g.,
Relay Number 03, if supervised,
is zone 603.
NOTE: Relay supervision
should be used only for relays
on the 4204CF modules.
800 830 ECP Device
Supervisory
Zones
8 + 2-digit Device Address;
e.g., Device Address 01, if
supervised, is zone 801.
970-977,
988, 990, &
997
System
Supervisory
Zones
970: Bell 1Output
971 Bell 2 Output
972 Earth Ground
973 J2 Input 1
(Communicator)
974 Dialer 1
975 Dialer 2
976 Auxiliary Relay
977 J2 Communicator
Trigger Outputs
988: 2
nd
Wireless Receiver
not receiving signals
990: 1
st
Wireless Receiver
not receiving signals
997: Polling Loop (short
circuit)
992, 995
999
Duress and
Keypad Panics
992: Duress
995: 1 + panic (A key)
996: 3 + # panic (C key)
999: + # panic (B key)
Supervisory zones should be given a response type of either 05
(Trouble by Day, Alarm by Night) or 19 (24-Hour Trouble).