Setup guide

VISTA-32FB Installation and Setup Guide
3-24
Wiring for the Remote Keyswitch
To install the Honeywell 4146 keyswitch, perform the following steps:
Step Action
1
Connect the
Honeywell 4146 to the panel as shown in Figure 3-22.
2 If you are using the tamper, make sure it is connected to a zone.
4146 KEYSWITCH
(READY)
GREEN
(ARMED)
RED
TO ZONE 8 + (TERM 27)
TO OUT 5 (J2 PIN 6)
TO ZONE 7 + (TERM 25)
TO ZONE 7/ZONE 8 - (TERM 26)
TO GND (J2 PIN 8)
TO OUT 1 (J2 PIN 7)
4146_keyswitch-001-V0
2000
OHMS
EOLR
2000
OHMS
820
OHMS
820
OHMS
TAMPER
SWITCH
(N.C.)
LOCK
SWITCH (N.O.)
Figure 3-22: Remote Keyswitch Wiring
Installing a Remote Keypad Sounder (For Commercial Burglary use only)
An optional Amseco PAL 328N Piezo Sounder can be used to duplicate the sounds produced by the keypad’s built-in
sounder. The remote sounder will duplicate all sounds (such as alarms, trouble beeps, etc.) except for the short beeps
associated with keypad key depression. One application of this feature would be to produce chime beeps at a distant
location from the keypads.
If used, program field 3
20 must be set to “0” and field 15 must be set to the desired partition number.
The remote sounder must be connected to the Output 5 on the J2 connector as shown in Figure 3-23.
123456 78 9
(GRAY)
(YELLOW)
(WHITE)
(RED)
(VIOLET)
(GREEN)
(BROWN)
BLUE
BLACK
J2 CONNECTOR
AMSECO PAL-328N
PIEZO SOUNDER
(10MA)
4142TR CABLE
J2_trigcon-006-V0
GROUND
OUT 1
OUT 5
OUT 2
INPUT 1
OUT 6
OUT 3
OUT 7
OUT 4
BLACK
RED
_
+
Figure 3-23: Remote Keypad Sounder Wiring
Communications Device Connected to the ECP Bus
The control can support IP or GSM Communications Device (7845i-ent, 7845GSM or 7845i-GSM) that connects to control
panel’s keypad terminals. All messages programmed for transmission via the phone lines may also be sent via the
Communications Device. These messages are transmitted in Contact ID format regardless of the format programmed
for the control in fields 45 and 47. The 7845GSM or 7845i-GSM communicators may currently be used for Commercial
Burglary systems only.
Contact ID format must be used in UL installations.
Supervision
The data lines between the control and the Communications Device, as well as certain functions in the Communications
Device, can be supervised.
If communication is lost or a trouble condition occurs, both the Communications Device and the control’s dialer can be
programmed to send a Trouble message to the central station.
NOTE: For complete information, see the Installation Instructions that accompany the Device.