6-12
Various System Trouble Displays (cont’d)
Busy-Standby dl If this remains displayed for more than 1 minute, the system is
disabled.
Modem Comm CC The system is in communication with the central station for
change of function or status verification.
no display no display Power Failure
If there is no keypad display at all and the LEDs are unlit,
operating power (AC and battery) for the system has stopped and
the system is inoperative.
If the message “AC LOSS” (Alpha display keypads) or “NO AC”
(Fixed-Word display keypads) is displayed, the keypad is
operating on battery power only.
If the battery standby capacity is used up during a prolonged AC
power outage, the control's power will shut down to minimize deep
discharge of the battery.
The display may also be blanked intentionally (except during exit
delay and for 30 seconds after disarming, or during a mains power
loss) if field *186 Display Options entry 2 is enabled.
Comm. Failure FC A communication failure has occurred.
Open Circuit OC The keypad is not receiving signals from the control and sees an
open circuit.
Long Rng Trbl bF Backup Alternative Communication Media communication failure.
Bell Failure 70 Siren supervision failure.
RCVR Jam 90 RF jam detected.
KEYPAD LOW BAT 00 BAT Wireless keypad low battery
Phone Okay Cd The dialer test has been successful (CID code 601).
Dialer Off dO The dialer is disabled.
Test in Progress dd Walk test mode is active(CID code 607).
Upload Completed dC The upload or download session was completed.
Upload Failed dF The upload or download session failed before completion.