Setup guide
Installation and Setup Guide
5-16
PROMPT
VALID
ENTRIES
EXPLANATION
“B”
01 Enter Zn type
Perimeter 03
Zone Type
see list at right
If zone type was selected, this screen appears. Otherwise skip to
the next row.
Enter the desired zone type associated with this output number.
See below for a list of available zone types.
CHOICES FOR ZONE TYPES:
00 = Not Used 05 = Trouble Day/Alarm Night 15 = Medical
01 = Ent/Exit #1 06 = 24 Hr Silent 16 = Fire w/verification
02 = Ent/Exit #2 07 = 24 Hr Audible 23 = No Alarm Response
03 = Perimeter 08 = 24 Hr Aux 24 = Silent Burglary
04 = Interior Follower 09 = Fire 77 = Keyswitch
10 = Interior w/Delay 81 = AAV Monitor Zone
12 = Monitor Zone 82 = Blockschloss
14 = Gas 90-93 = Configurable
CHOICES FOR SYSTEM OPERATION:
20 = Arming–Stay 41 = **AC Mains Failure 67 = Siren Fail
21 = Arming–Away 42 = **System Batt Low 68 = Telecom Line Cut
22 = Disarming 43 = Comm. Failure 69 = Telecom Line
Rstore
31 = End of Exit Time 46 = Sys Batt Restore** 70 = AC Mains Restore**
32 = Start of Entry Time 52 = Kissoff 71 = System Startup/
Clock Not
33 = Any Burglary Alarm 54 = Fire Zone Reset Set
36 = **At Siren Timeout*** 58 = Duress 72 = Clock Set
38 = Chime 60 = AAV 78 = Keyswitch Red LED
39 = Any Fire Alarm 66 = Function Key† 79 = Keyswitch Green
LED
40 = Bypassing 80 = Tamper Fault
** Use 0 (Any) for Partition No. (P) entry.
*** Or at Disarming, whichever occurs earlier.
†
Use *57 Menu Mode to assign the function key (function “07”).
Note: In normal operation mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Enter the partition in which this zone type will occur.
01 Partition 0 = any partition; 1 = partition 1;
Any partition 0 2 = partition 2; 3 = partition 3
Press [
∗
] to continue and skip to the “Output Action” prompt.