Setup guide

Data Field Programming
4-17
FIELD
TITLE and DATA ENTRIES EXPLANATION
*180
Zone Bypass Limit
0 = unlimited zone bypasses in each partition
1-7 = number of zone bypasses allowed in
each partition
8 = zone bypass disabled (no zones can be
bypassed)
Select the maximum number of zones that can be
bypassed.
Each partition individually uses this entry.
*181
AC and Clock Display Options
0-15 = desired options based on chart at right.
Use the following table to select the desired options
for real-time clock synchronization (50Hz, 60Hz,
Crystal), AC loss display (independent of AC loss
report enabled in *62), and clock display (time
displayed on bottom line of alpha keypads).
X10 NOTE: “X10” (powerline carrier devices) use the
selected AC frequency to communicate with the
control.
Entry AC Freq. Crystal for AC Loss disp Clock disp
0 60Hz clock backup no no
1 50Hz clock backup no no
2 60Hz clock no no
3 50Hz clock no no
4 60Hz clock backup yes no
5 50Hz clock backup yes no
6 60Hz clock yes no
7 50Hz clock yes no
8 60Hz clock backup no yes
9 50Hz clock backup no yes
#+10 60Hz clock no yes
#+11 50Hz clock no yes
#+12 60Hz clock backup yes yes
#+13 50Hz clock backup yes yes
#+14 60Hz clock yes yes
#+15 50Hz clock yes yes
*182
Summer Time Switchover Day
0 = switch on Sunday morning
1= switch on Saturday morning
2 = switch on Friday morning
Select the appropriate summer time switchover day.
*183
Date/Time Format
0 = 12-hour time/MMDDYY date
1 = 12-hour time/DDMMYY date
2 = 24-hour time/MMDDYY date
3 = 24-hour time/DDMMYY date
Select the desired time and date format.
*185
Downloader Suppression Options
0 = no suppression
1 = suppress user code viewing
2 = suppress commands and program
download when armed
3 = suppress user code viewing, commands,
and program download when armed
Select the desired options.