Setup guide

Data Field Programming
4-13
FIELD
TITLE and DATA ENTRIES EXPLANATION
*94
Download Phone Number
Enter up to 30 digits as follows: 0–9, # +11 for “”, #
+ 12 for “#”, # + 13 for a pause.
Enter the phone number of the downloading
computer.
Do not fill unused spaces. End field by entering .
To clear entries from field, press 94.
*95
Ring Count For Downloading
0 = Disable Monitoring Station initiated downloading
1–14 = number of rings before control answers
incoming call
#+15 = Answering machine/fax defeat
Refer to the chart below and program this field
accordingly.
phone answer/fax down-
module machine loading Set field
95 to…
yes no no 1-14 (not 0)
yes yes no higher than
number of rings
set on answer/fax
machine (e.g., if
ans/fax machine is
4 rings, set this
field to 5). This
allows access via
the phone module
if the answer/fax
machine is turned
off.
yes no yes 1-14 (not 0)
yes yes yes 15 (bypasses
answer/fax
machine
)
no no no 0
no yes no 0
no no yes 1-14
no yes yes 15
NOTE: If “15” is entered to bypass an answering
machine and a TeleCommand Phone Module is included
in the system, you should note the following:
When calling in from an off-premises phone, the user
should make the initial call, allow 1 or 2 rings only, then
hang up, then call again. The phone module will now
seize the line, and 2 long tones sound, followed by the
usual voice prompt for the access code. If this procedure is
not followed, phone module operation will not be possible.
Pager Programming Fields
FIELD
TITLE and DATA ENTRIES EXPLANATION
*160
Pager 1 Phone No.
Enter up to 20 digits
If you enter fewer than 20 digits, exit by pressing
[] and next field number. To clear entries from
this field, press 160.