Setup guide
Data Field Programming
4-9
FIELD
TITLE and DATA ENTRIES EXPLANATION
*69
Alarm Restores
Send restore code (if fault cleared):
0 = at siren timeout (if restored) or at disarm
(whether restored or not)
1 = dynamically as the fault clears
2 = only after a disarm
Alarm restore message will be sent upon condition
selected.
*70
Alarm Restore Report Code
0 = disable; 1-F = see description above ∗59
Sent when an alarm zone is restored to its non-
faulted condition or at the times selected in field
*69.
*71
Trouble Restore Report Code
0 = disable; 1-F = see description above ∗59
Sent when a trouble in a zone is restored
*72
Bypass Restore Report Code
0 = disable; 1-F = see description above ∗59
Sent when a zone that has been bypassed is
unbypassed, either manually or when the
partition/system is disarmed.
*73
AC Mains Restore Report Code
0 = disable; 1-F = see description above ∗59
Sent when AC mains has been restored after an AC
mains outage.
*74
Low Battery Restore Report Code
0 = disable; 1-F = see description above ∗59
Sent when a system low-battery condition is
restored to normal.
*75
RF Low Battery Restore Code
0 = disable; 1-F = see description above ∗59
Sent when a transmitter’s low battery condition is
restored (i.e., new battery installed).
*76
Test Restore Report Code
0 = disable; 1-F = see description above ∗59
Sent when the Test mode is exited.
Miscellaneous System Fields
FIELD
TITLE and DATA ENTRIES EXPLANATION
*77
Summer Time
Start/End Month
0 = Disabled 4 = April
1 = Jan # + 10 = Oct
2 = Feb # + 11 = Nov
3 = Mar # + 12 = Dec
Enter the start and end month for summer time, if
applicable to the region.
*78
Summer Time
Start/End Weekend
0 = disabled 4 = fourth
1 = first 5 = last
2 = second 6 = next to last
3 = third 7 = third to last
Enter the start and end weekend for summer time,
if applicable to the region.