Setup guide

Installation and Setup Guide
4-4
FIELD
TITLE and DATA ENTRIES EXPLANATION
*38
Confirmation Of Arming Ding
Entry 1: 0 = no; 1 = yes, 1-second ding
(ding if armed from wired keypad)
Entry 2: Enter 0-15 from table below.
(ding if armed from RF device)
Entry Ding at Siren Trigger 2 Output
0 none none
1 none 250mS
2 none 1 second
3 none 4 seconds
4 250mS none
5 250mS 250mS
6 250mS 1 second
7 250mS 4 seconds
8 1 second none
9 1 second 250mS
#+10 1 second 1 second
#+11 1 second 4 seconds
#+12 4 seconds none
#+13 4 seconds 250mS
#+14 4 seconds 1 second
#+15 4 seconds 4 seconds
Entry 1 for each partition selects whether arming
from wired keypads causes siren ding.
Confirmation of arming is an external sounder
“ding” that follows the time selected in entry 2 for
“ding at siren.” Ding occurs when closing reports is
sent, or when exit delay expires.
Entry 2 for each partition selects whether arming
from remote RF devices causes siren ding and/or
activates trigger 2 output; also selects siren
ding/trigger activation duration (arm = 2 dings of
selected duration with 1 second off between; disarm
= 1 ding of selected duration). Ding occurs upon
reception of the wireless arming command.
NOTE: If using an option that activates trigger 2,
trigger 2 must be dedicated to only this function;
do not assign any other functions to trigger 2.
*39
Power-Up In Previous State
0 = always power-up in a disarmed state
1 = assume the system status prior to power
down
When the system powers up armed, an alarm will
occur 1 minute after arming if a zone is faulted at
that time.
Note that if the previous state was armed AWAY or
STAY, the system will not respond to sensor
changes for 1 minute, which allows time for sensors
such as PIRs to stabilize.
Dialer Programming (
40 –
55)
FIELD
TITLE and DATA ENTRIES EXPLANATION
*40
PABX Access Code
Enter up to 6 digits if PABX is needed to access
an outside line. Do not fill unused spaces.
0–9, # + 11 for ‘’, # + 12 for ‘#’, # + 13 for a
pause (2 seconds)
To clear entries from field, press 40. If fewer than
6 digits need to be entered, exit by pressing [],
which advances to the next field.
Call Waiting: If the subscriber’s phone service has
“call waiting” (and is not using PABX), enter “*70”
(“# + 11”) plus “# + 13” (pause) as the PABX entry
to disable “call waiting” during control panel calls.
If the subscriber does not have “call waiting” and is
not using PABX, make no entry in this field.
*41
Primary Phone No.
Enter up to 30 digits. Do not fill unused spaces.
0–9, # + 11 for ‘’, # + 12 for ‘#’, # + 13 for a
pause (2 seconds)
If you enter fewer than 30 digits, exit by pressing
[]. To clear entries from field, press 41.
NOTE: Backup reporting (in which 8 calls are
made to the secondary phone number if no kissoff is
received after 8 attempts to the primary number) is
automatic only if there is a secondary phone
number (field 42).