Setup guide
Installation and Setup Guide
3-10
Table of Device Addresses
This Device Uses Address
Reports as
††
Enabled By…
RF Receiver 00 100 *56 zone programming: input device type entry
AUI 1 01 101 automatic if AUI enable field *189 enabled for AUI 1
AUI 2 02 102 automatic if AUI enable field *189 enabled for AUI 2
Alternative Communication
Media (ACM)
†
03 103 automatic if output to ACM field *29 enabled
Telecommand Voice Module 17-23 117-123 same as keypad enables; see below
Zone Expanders** (4219/4229):
zones 17 - 24
08
108
*56 zone programming: input device type entry, then:
automatic if zone no. 17-24 entered as AW type or
relay assigned
Relay Module (4204/6164): 13 113 entered at device address prompt
Keypads:
keypad 1
keypad 2
keypad 3
keypad 4
keypad 5
keypad 6
keypad 7
keypad 8
16
17
18
19
20
21
22
23
116
117
118
119
120
121
122
123
data field programming as listed below:
always enabled for partition 1, all sounds enabled.
data field *190
data field *191
data field *192
data field *193
data field *194
data field *195
data field *196
5800TM Module 28 n/a automatic
† ACM devices include: 7845i Ethernet Interface Internet/Intranet, AI4164RS/AI4164ETH
RS485/Ethernet Eureka Network Interface
†† Addressable devices are identified by “1” plus the device address when reporting. Enter a report
code for zone 91 to enable addressable device reporting (default = reports enabled). See field *199
for addressable device (ECP) 3-digit/2-digit identification keypad display options.
** or 6164 Keypad using zones; 08 = zones 17-20