Setup guide

Programming Overview
3-9
Data Field Programming Procedures (cont’d)
Task Procedure
Entering Data When the desired field number appears, simply enter the digits
required. The keypad beeps three times after the last digit is entered
and automatically displays the next data field in sequence.
If entering less than the maximum digits available (e.g., phone
number field), enter the desired digits, then press [
] to end the
entry.
Review a Data Field Press [#] + [Field Number].
That field’s data is displayed, but no changes can be made.
Deleting an Entry Press [
] + [Field No.] + [
] (applies only to phone number, account
number, and pager character fields).
Interactive Mode Programming (
56,
57,
58,
79,
80,
81,
82,
83)
Entering Interactive Mode
Press [
] + [Interactive Mode No.] (for example,
56) while in
Program Mode. The Alpha display keypad will display the first of a
series of prompts requesting entries.
After making the appropriate entry, press the [] key to accept the
entry and continue to the next prompt.
Loading Factory Defaults/Initializing for Download
To Load Default Entries Data Field, System, and Zone Defaults: The VISTA-12A and VISTA-
12E each have two unique sets of default entries. The complete default
tables are listed in the Programming Guide.
Press 97 while in Program Mode, then press 1 or 2 to load the desired
set of factory defaults (default set 1 or default set 2). This resets all data
fields to the respective default set values shown in the Programming
Guide.
User Code Defaults: To reset only the user codes to default values,
press 97, then press 3.
To Initialize Download ID Press 96 while in Program Mode. This initializes the system for
downloading and resets all the subscriber account numbers and CSID.
Do not press
97 to load defaults if any programming has been done previously—data
already programmed into the system will be changed!
Exiting the Programming Mode
Prevent installer code reentry Press 98. Exits Programming Mode and prevents re-entry by:
Installer Code + [8] + [0] + [0]. To enter the programming mode if
98 was used to exit, you must first power the system down. Then
power up again, and press [] and [#] at the same time, within 50
seconds of powering up.
Allow installer code reentry Press 99. Exits Programming Mode and allows re-entry by:
Installer Code + [ 8] + [0] + [0] or by: Pressing [] and [#] at the same
time, within 50 seconds of power-up.