Setup guide
Installation and Setup Guide
2-16
Powerline Carrier Devices
1. Install up to 4 powerline carrier devices (if no
relays are used) according to the instructions
included with each.
2. Connect the Powerline Interface Modulator to
the Trigger Module connector using
SA4120XM-1 cable as shown below.
3. Use Programming Mode to enter the device
house ID in data field*27, and enter the unit
code using *79 Output Device menu Mode.
Notes
• When using Powerline Carrier devices,
you must use a Powerline Carrier Device
Modulator. It supplies signals from the
control panel through the premises AC
mains wiring to the Powerline Carrier
devices (which are plugged into AC
outlets). You can then make devices that
are plugged into Powerline Carrier devices
perform various functions in response to
commands you enter at the security
system keypads.
78
(USE SA4120XM-1CABLE)
SYNC BLK)
COM (VIO)
DATA (BLU)
TO X-10
TRANS.
123 4 56
SUPV
TRIG 1
TRIG 2
( ) VTRIG
( ) AUX
( ) GND
TRIGGER MODULE
NOT USED
V48A-V48E-004-V0
Trigger Module Powerline Interface Connections