*56 ZONE PROGRAMMING WORKSHEET [default values shown in brackets]
Zone Zn Type Partition Report Basic Wired Type Response Time Location
1
[01] [1]
[yes]
[EOL] [1]
2
[04] [1]
[yes]
[EOL] [1]
3
[03] [1]
[yes]
[EOL] [1]
4
[03] [1]
[yes]
[EOL] [1]
5
[03] [1]
[yes]
[EOL] [1]
6
[03] [1]
[yes]
[EOL] [1]
Zone Zn Type Partition Report Input Type Loop Serial Number Location
9
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
49
[1]
[yes]
[BR]
50
[1]
[yes]
[BR]
51
[1]
[yes]
[BR]
52
[1]
[yes]
[BR]
53
[1]
[yes]
[BR]
54
[1]
[yes]
[BR]
55
[1]
[yes]
[BR]
56
[1]
[yes]
[BR]
57
[1]
[yes]
[BR]
58
[1]
[yes]
[BR]
59
[1]
[yes]
[BR]
60
[1]
[yes]
[BR]
61
[1]
[yes]
[BR]
62
[1]
[yes]
[BR]
63
[1]
[yes]
[BR]
64
[1]
[yes]
[BR]
91
[05] N/A
[yes]
N/A N/A N/A Addressable Device Report
92
N/A N/A
N/A N/A N/A Duress Report
95
[00]
N/A N/A N/A
keypad [1] / [∗]
96
[00]
N/A N/A N/A keypad [3] / [#]
99
[07]
[yes]
N/A N/A N/A
keypad [∗] / [#]
NOTES:
Zone Type: see chart on next page
Basic wired Type (zns 1-6):
0 = EOL
1 = NC
2 = NO
3 = zone doubling
4 = double-balanced
Input Type:
2 = AW (zones 17-24)
3 = RF (zones 9-24)
4 = UR (zones 9-24)
5 = BR (zones 49-64)
7 = RM (zones 9-24)
NOTE: Zones 9-14 not available depending on whether zone
doubling enabled on zones 1-6.
Report:
yes = Contact ID reporting enabled for this zone; entered as 01 00 in appropriate data
fields.
Response Time:
0 = 10msec
1 = 400msec
2 = 700msec
3 = 1.2 sec
NOTE: If zone doubling is selected, the response time selected for the basic zone
automatically applies to the associated doubled zone.
Reserved Zones
91 =
addressable device report enable/disable
default zone type = [05].
92 = Duress report enable/disable