187 Sounder Mimic on Trigger 1 [0]
0 = no sound output on trigger 1
1 = mimic keypad 1, address 16 5 = mimic keypad 5, address 20
2 = mimic keypad 2, address 17 6 = mimic keypad 6, address 21
3 = mimic keypad 3, address 18 7 = mimic keypad 7, address 22
4 = mimic keypad 4, address 19 8 = mimic keypad 8, address 23
NOTE: If used, do not assign any other functions to trigger 1.
188 Keypad Sabotage Options [0,0]
Entry 1: Keypad Lockout: 0 = disable; 1 = enable 15 minute lockout
NOTE: 461 Wrong Code Entry is sent only if Contact ID
format is selected as reporting format in field *48 (if
Contact ID format is not being used, this event is not
reported)
Entry 2: Keypad Supervision and Tamper Fault Detection:
0 = no, 1 = yes
NOTE: All lockout, supervision, and tamper events are recorded in
the event log regardless of the settings in entries 1 and 2.
189 AUI Device 1 and 2 Enable [0,0]
(for Touch Screen Style Keypads) AUI 1 AU2
System supports up to two touch screen style keypads (e.g., Symphony
Advanced User Interface, and 6270 Touch Screen Keypad).
AUI Compatibility Note: To ensure proper AUI device operation, use
AUI devices with the following rev levels: 6270 series use version
1.0.9 or higher; 8132/8142 (Symphony) series use version 1.1.175 or
higher.
Touch Screen (AUI) device 1: Must set AUI device address to 1
Touch Screen (AUI) device 2: Must set AUI device address to 2
Enter each AUIs home partition.
0 = disabled
1 = partition 1; 2 = partition 2; 3 = common partition
KEYPAD OPTIONS
NOTES: 1. Keypad 1 (addr 16) options are factory set and cannot be changed.
2. Each keypad must be assigned a unique address. Keypads
programmed with the same address will give unpredictable results.
190 Keypad 2 Device Address 17 [0] [0]
Partition: 0 = keypad disabled; 1-3 = part. no. Part. Sound
Sound: 0 = no suppression
1 = suppress arm/disarm and E/E beeps
2 = suppress chime beeps only
3 = suppress arm/disarm, E/E, & chime beeps
Fields*191-*196 see field 190 for entries.
Part. Sound
191 Keypad 3 Device Address 18 [0] [0]
192 Keypad 4 Device Address 19 [0] [0]
193 Keypad 5 Device Address 20 [0] [0]
194 Keypad 6 Device Address 21 [0] [0]
195 Keypad 7 Device Address 22 [0] [0]
196 Keypad 8 Device Address 23 [0] [0]
197 Exit Time Display Interval [1]
0 = no display; 1-5 = seconds between display refresh
198 Display Partition Number [0]
0 = no; 1 = yes (partition number displays on alpha keypads)
199 ECP Device Fail Display [0]
0 = 3-digit display (1 + device address); for 6148, 6164
1 = 2-digit fixed-display as 91; for 6128 series keypads