Installation manual
– 17 –
*83 CONFIGURABLE ZONE TYPE PROGRAMMING
CONFIGURABLE ZONE TYPE WORKSHEET
Option ZT 90 ZT 91 ZT 92 ZT 93 Option Selections
Zone Attributes
Bypass Option
Response to Short
Response to Open
Vent Zone
Zone Processing
Sound on Trouble
Sound on Alarm
Dial Delay
Display Options
Contact ID Code
Zone Attributes
0 = none
1 = exit delay only
2 = entry/exit 1
3 = entry/exit 2
4 = follows entry/exit
5 = has verification†
6 = resettable
Bypass Options
0 = cannot be bypassed
1 = auto bypassed when
armed STAY
Response to Short/Open
0=none 2=trouble
1=Alarm 3=fault
Vent Zone
0=no; 1=yes
Zone Processing
0=none
1 = Zone type has
automatic restore
2 = zone type uses Misc.
Fault Delay Time and
automatic restore
Sound on Trouble
0=none
1=1 beep every minute
2= fast beeps normal
Sound on Alarm
0=none
1= keypad sound only
2= steady siren sounding
3= pulsing siren (temporal)
Dial Delay
0=no; 1=yes
Display Options
0=no display
1=display only
2 = chime only
3 = chime & disp.
Contact ID Code
000-999
Start Configurable Zone Type Programming Mode by pressing ∗
∗∗
∗
83
while in Data Programming mode.
Enter Zone Type
(00=quit) 90
Enter the configurable zone type number being programmed.
90-93
[∗] to continue
90 Zn Attributes
0
Enter the desired zone attributes.
0 = none 4 = follows entry/exit
1 = exit delay only 5 = has verification (resets power upon event and when code + OFF to clear
2 = entry/exit 1 condition. If condition persists, zone activates)
3 = entry/exit 2 6 = resettable (upon code + OFF)
NOTE: If 6 is selected for the Zone Attribute, enter 0 for Alarm/Trouble Processing at the below Alm/Trbl
Proc prompt.
[∗] to continue
90 Bypass Option
0
Enter the desired bypass option.
0 = zone type cannot be bypassed
1 = auto bypassed when armed in stay mode
[∗] to continue
90 Resp to Short
Armed 0 DArmd 0
Select the type of response when zones assigned to this zone type are shorted when the system is armed.
0=none 2=trouble NOTE: • For double-balanced zones, this entry must be 0.
1=alarm 3=fault • For zone-doubled zones, both zones of the doubled pair must
[∗] to continue be assigned the same response to a short.
90 Resp to open
Armed 0 DArmd 0
Select the type of response when zones assigned to this zone type are opened when the system is armed.
0 = none 2 = trouble
1 = alarm 3 = fault
[∗] to continue
90 Vent Zone
0 = No, 1 = Yes
If selected, the system can be armed even if zones assigned to this zone type are faulted.
NOTE: After arming, faults on these zones will be ignored until the zone is restored.
0=no; 1=yes; [∗] to continue
90 Alm/Trbl Proc
0
Select desired actions for zones assigned to this zone type.
0=none; 1=Zone type has automatic restore; 2=zone type uses Misc. Fault Delay Time (selected in field *87)
and automatic restore
NOTE: If 6 was selected above for the Zone Attribute, enter 0 for this prompt.
[∗] to continue
90 TRBL SOUND
0
Select type of sounding upon trouble conditions on zones assigned to this zone type.
0=none; 1=one beep every minute; 2= normal trouble sound (fast beeps)
[∗] to continue
90 ALARM SOUND
0
Select type of sounding upon alarm conditions on zones assigned to this zone type.
0=none; 1= keypad sound only; 2= steady siren sounding; 3= pulsing siren (temporal)
[∗] to continue
90 Dial Delay
0=No, 1=Yes
If selected, faults on zones assigned to this zone type will delay reporting for whatever length of time that is
selected in dial delay (*50)
0=no; 1=yes; [∗] to continue
90 Disp Option
1
Select whether faults on zones assigned to this zone type are displayed at the touch pad and/or cause a
chime sound.
0=no display; 1=display only; 2 = chime only; 3 = chime & disp.
[∗] to continue
Alarm ID: 000
Trouble ID: 000
Enter the desired 3-digit (000-999) Contact ID report codes for faults and troubles occurring on zones
assigned to this zone type.
[∗] to continue; returns to Enter configurable zone type number prompt.
IMPORTANT: Make sure the code does not conflict with existing, predefined Contact ID report codes. See
the
System Communication