OUTPUT RELAYS/POWERLINE CARRIER DEVICES WORKSHEET FOR ∗
∗∗
∗79, ∗
∗∗
∗80 and ∗
∗∗
∗81.
For keypad activated devices, use *79 Menu mode to assign a system output number and associate its corresponding device.
For automatic activation, use *79 Menu mode as above, and use *80 Menu mode to define the system condition that will
activate/deactivate the device(s).
∗
∗∗
∗79 RELAY/POWERLINE CARRIER DEVICE MAPPING (Must program before using *80)
OUTPUT TYPE
OUTPUT TYPE
Relay X10
Relay X10
Output
No.
Module
Addr.
Pos
(1-4)
Unit
No.
Description
Output
No.
Module
Addr.
Pos
(1-4)
Unit
No.
Description
01
17
On-Board Trigger 1
Norm output =
02
03
18
On-Board Trigger 2
Norm output =
[default: 1, trig. normally low
04
To Activate/Deactivate Devices in Normal Operating Mode:
Code + # + 7 + NN Key Entry starts Device NN.
Code + # + 8 + NN Key Entry stops Device NN.
Start Output Device Mapping by pressing *79 while in Data Programming Mode.
ENTER OUTPUT NO.
00 = QUIT xx
Enter the logical (or reference) relay number as used in the system.
01-04 = relays/X-10
17-18 = on-board triggers (can be programmed for inverted output; see next prompt)
[∗] to continue
17 OUT NORM LOW
0 = NO 1 = YES 0
This prompt appears only for triggers 17 and 18.
0 = no (standard default); sets the trigger output level normally high
1 = yes; sets the trigger output normally low (can be used for resetting 4-wire smoke detectors by connecting
trigger wire to the negative power terminal of the smoke detector, selecting 1 at this prompt, and setting
as zone type 54, fire zone reset, in *80 Menu mode)
[∗] to return to Output Number prompt
XX OUTPUT TYPE
DELETE? 0
Select whether this is a relay or a Powerline Carrier (X-10) device.
0 = delete this output number
1 = relay on 4204/4229 module, 6164 keypad (skip to “B” prompt)
2 = Powerline Carrier device (go to “A” prompt)
[∗] to continue
“A”
XX UNIT No.
yy
Enter the device’s unit code (set at the device)
01-04 = predefined address
[∗] to returns to the Output Number prompt
“B”
XX MODULE ADDR
07-15 yy
Enter the module’s predefined address (set the module’s DIP switches to the selected address, or key the
6164 address)
07-15 = predefined address (see table of device addresses)
[∗] to continue
XX REL POSITION
1-4 zz
Enter the actual (or physical) relay number with respect to the Relay Module upon which it is located. For
4204 modules, relay numbers are 1-4. For 4229 modules, relay numbers are 1-2. For 6164 keypad, relay
number is 1.
1-4 = relay position
[∗] to return to the Output Number prompt for programming the next device