Operating instructions

While configuring the keyboard, the COMMUNICATIONS / TELEMETRY submenu ( see § 4.2.3.2
-Telemetry , page 24), should be set as follows:
A-Connector
Telemetry
A-Protocol ENEO (*)
A-Baudrate 2400
B-Connector Telemetry
B-Protocol ENEO (*)
B-Baudrate 2400
(*) Any protocol present in the keyboard.
All telemetry commands will be sent directly to the keyboard connectors. Only video control commands are
sent to the matrix.
5.4.6.3 Mixed telemetry control (matrix/keyboard)
While configuring the keyboard, the COMMUNICATIONS / TELEMETRY submenu (see § 4.2.3.2
-Telemetry , page 24), should be set as follows:
A-Connector
Telemetry
A-Protocol ENEO (*)
A-Baudrate 2400
B-Connector Telemetry
B-Protocol -------------------
B-Baudrate -------------------
(*)Any protocol present in the keyboard.
In this case all telemetry A commands will be sent directly to keyboard A connector using the protocol
selected on the keyboard. All telemetry commands of cameras with settings on the B line will be sent to the
matrix which in turn will send them along the P&T line. The telemetry protocol is set in the video matrix.
T o set the cameras on line A or B (see § 4.2.4.1.1 - Cameras with a matrix connection, page 27).