4.2.4.4.1 Individual setting for external multiplexer
Position the cursor to correspond with the multiplexer to be modified and press the key.
If the multiplexer has been deactivated it will be activated and vice versa.
Exit menu key
Cursor shift key
Cursor shift key
Key for activating/deactivating the multiplexer corresponding to the cursor position
4.2.4.5 Functions
Position the cursor to correspond with the camera to be modified and press the key. If the function has been
deactivated it will be activated and vice versa.
These parameters directly influence the screen display of the commands in the various menus. For
example, if the ā€œAUTOPAN/SCANā€ parameter is not enabled the operator will not be allowed to
enter the corresponding menus and there will be a message saying ā€œFunction disabledā€.
PARAMETER FUNCTION
Matrix/mux setup
Enables the keyboard to carry out the functions to modify the parameters for the
matrix/multiplexer connected to the keyboard.
Telemetry setup
Enables the keyboard to carry out the functions to modify the parameters for the
dome or receiver connected to the keyboard.
Autopan/Scan/Patrol
Enables the keyboard to carry out the automatic dome movement functions
Joystick
Enables the keyboard to accept movement controls from the joystick.
Up/Dw camera
Enables the controls to move up and down the cameras (only for matrixes)
Change receiver No.
Enables the option to change the association between camera and dome/receiver
address.
Change monitor No.
Enables the option to select the monitors.
Zoom/Focus/Iris
Enables the option to change the values of ZOOM, FOCUS and IRIS.