Operating instructions
Procedure for configuring Patrol SA for the Preset positions:
To change the common pause length, go to the item “ Send default pause” and press the key. Insert
the desired value and confirm with the ENTER key.
To change the pause length for an individual position, go to the item “ Send specific pause” and press the
key. Insert the position number and the desired pause length.
Exit the menu and start the Patrol SA.
6.17.10 Preset, Scan and Home
The PRESET, SCAN and HOME functions are as described in the general explanation with the following
limitations specific of the dome (see § 4.4.7.1 - Preset, pag.47 and see § 4.4.8 - SCAN MENU, pag.49).
Type Minimum position Maximum position Notes
PRESET 1 99(*)
SCAN 1 99(*)
HOME Carry out the SCAN command to
position 1 (**).
(*) maximum 40 positions for the DTRX3
(**) function inactive for the DTRX3
6.17.11 Function keys
From the MAIN menu press the FUNCTION KEYS key to enter the menu for carrying out the specific controls.
F1
Associated function: “ Set Home position”.
F2
Associated function: “ Reset Home position”.
F3
Associated function: “ Reset receiver sent”.
Page 191 of 193 MNVADCT _0409