Operating instructions
6.8.9 Preset, Scan and Home
The PRESET, SCAN and HOME functions are as described in the general explanation with the following
limitations specific to the dome (see § 4.4.7.1 - Preset, pag.47 e see § 4.4.8 - SCAN MENU, pag.49).
Type Minimum position Maximum position Notes
PRESET 1 32
SCAN 1 32
HOME Carries out the SCAN command to
position 1.
6.8.10 Special codes
Go to the special code insertion screen (see § 6.1.5 - Organising the configuration menus , pag.98).
Some parameters can be configured by inserting a special code.
Number Function
0
Position of PAN 0.
SPEED CURVES
11 First speed curve
12 Second speed curve
13 Third speed curve
14 Fourth speed curve(default)
ZONE
20
Start the SCAN of the zone.
21
End the SCAN of the zone.
10X
Set the start of the zone, with X from 1 to 8.
20X
Set the end of the zone, with X from 1 to 8.
LENSES
40
AUTOFOCUS On.
41
AUTOFOCUS Off.
42
Automatic AUTOFOCUS on.
AUTOIRIS
50
AUTOIRIS On.
51
AUTOIRIS Off.
52
Automatic AUTOIRIS On.
ON SCREEN INFORMATION
Page 142 of 193 MNVADCT _0409