Operating instructions
6.7 PANASONIC Domes
6.7.1 Materials and reference documents
Panasonic WV-CS600 and Panasonic WV-CS850 Domes
Protocol Information WV-CS850 ver 2.2, Nov.28, 2001
Protocol Information WV-CSR600, WV-CSR400, WV-BSR300 ver 5.3, Nov.27, 1997
6.7.2 Important note regarding the protocols
The Panasonic protocols allow the control of a range of domes with somewhat different specifications.
Because the complete protocols have been implemented, it is possible that the controls described below can be
used for both the WV-CS600 and WV-CS850 models, or are specific to only one model. Wherever possible,
this distinction is made in the following sections. Nevertheless, we advise checking the manual of the dome
that is to be controlled, to find out which controls are actually available.
6.7.3 Connecting the dome hardware
White
RS485A
Yellow
Yellow
RS485B
Green
IMPORTANT NOTE
Even though the two Panasonic dome control protocols (Panas600 and Panas850) are
compatible to a certain extent, choosing the more appropriate protocol will improve control of
the dome.
Set “Conventional Protocol ”, LOCAL (not REMOTE)
8 data bits, no parity, 1 stop bit , Full Duplex Wait time = 0
Page 131 of 193 MNVADCT _0409