Operating instructions
6.4 ERNITEC SATURN Dome
6.4.1 Materials and reference documents
Ernitec Saturn Dome
ICU Installation Instruction, Manual No.3040-00014, Rev.980220
6.4.2 Connecting the dome hardware
White
RS485A
Rx+
Yellow
RS485B
Rx-
6.4.3 Configuration
The dome is mostly configured by On Screen Menu.
Some parameters can be configured by inserting a special code.
For all dome configuration operations SETUP TELEMET RY must be enabled.
Connect the dome directly to the keyboard and a monitor to the dome video output following the general
procedure (see ยง 6.18 - Procedure for setting a dome/receiver in operation, pag.191). Go to the dome OSM
configuration screen.
T he screen that appears allows access to dome OSM configuration.
ENTER PROGRAMMING
Used to enter the dome OSM.
UP/DOWN ARROWS
To shift within the dome menus and change the values
LEFT/RIGHT ARROWS
Correspond to the Previous and Next keys shown in the dome manual.
ENTER MENU
Used to enter the submenus and to confirm data changes.