Operating instructions
6.3.11 Special codes
Go to the special code insertion screen (see ยง 6.1.5 - Organising the configuration menus , pag.98).
Some parameters can be configured by inserting a special code.
Number Function
AUTOPAN
400 Store the current position as the first limit switch
401 Store the current position as the second limit switch
402 The movement is made to the right
403 The movement is made to the left
41X X=1..4 autopan speed from slow (X=1) to fast(X=4)
Note: the change in speed is used the next time autopan is restarted
SCAN
X X=1..128 slow scan to preset position X
SEQUENCES AND CRUISE
20X X=1..4 start sequence number X
300 Cruise function on
OTHER FUNCTIONS
350 Identification text hidden
351 Identification text shown
360 Title hidden
361 Title shown
9999 Dome reset
Page 114 of 193 MNVADCT _0409