Operating instructions
Number Function
2300
Movement at maximum speed
230X
(1÷8) reduced speed of movement
TIMER FUNCTIONS
40XX
(00÷56): stop autopan
00: continuous; 01÷23: from 5 to 115 minutes (step=5 minutes); 24÷44: from 2 to 12
hours (step=30 minutes); 45÷56: from 13 to 24 hours (step=1 hour)
4XXX
(1÷8, 00÷28): reset aux. contacts
The first X digit indicates contact number 1÷8, the last two indicate the time:
00: continuous; 01÷05: from 1 to 5 minutes (step=1 minute); 06÷15: from 10 to 55
minutes (step=5 minutes); 16÷27: from 1 to 12 hours (step=1 hour); 28: 24 hours
49XX
(00÷28): stop wiper*
50XX
(00÷28): stop pump*
51XX
(00÷28): stop lighting*
52XX
(00÷28): stop heating*
53XX
(00÷28): stop fan*
*) 00: continuous; 01÷04: from 5 to 20 seconds (step=5 seconds); 05: 30 seconds; 06: 45
seconds; 07÷11: from 1 to 5 minutes (step=1 minute); 12: 10 minutes; 13: 15 minutes; 14:
30 minutes; 15: 45 minutes; 16÷27: from 1 to 12 hours (step=1 hour)
60XX
(00÷37): return to home position (preset number 1)
00: function disabled; 01÷06: from 5 to 30 seconds (step=5 seconds); 07: 45 seconds;
08÷16: from 1 to 9 minutes (step=1 minute); 17÷26: from 10 to 55 minutes (step=5
minutes); 27÷32: from 60 to 110 minutes (step=10 minutes); 33÷37: from 2 hours to4
hours (step=30 minutes).
DIGITAL ZOOM
90
Off
91
On
92
4x
93
16x
SHUTTER
200
Off
201
On
202
Automatic
High Speed
211
Flickerless (PAL: 1/120sec, NTSC: 1/100sec)
212
1/125sec
213
1/250sec
214
1/500sec
215
1/1000sec
216
1/2000sec
Page 106 of 193 MNVADCT _0409