Specifications

4–1
SECTION 4
Initial Setup
In This Section
Programming the Conrol
Panel
6270 Initialization
How to Change the ECP
Address
How to Access the Central
Station Screen
6270 Setup
Setting Chime Mode On/Off
Programming the Control Panel
The 6270 will not be fully operational unless its address in the control
panel has been enabled for an alpha console, AUI type device, and
assigned to a partition (where applicable). Refer to Compatibility on
page 12 of this document for the quantity of 6270s that may be used
and the required control panel software revision level.
On residential control panels (VISTA-20PS or equivalent), two
6270s may be used (addresses 1 and 2). These addresses (in field
*189) are enabled by default. If the defaults have been changed,
enable these addresses (in field *189) using an alpha-keypad and the
Data Field Programming procedures located in the panel Installation
and Setup Guide.
On commercial control panels (VISTA-128BP, VISTA-128FBP,
or equivalent), addresses between 1 through 30 may be used for the
6270. These addresses in the control panel are normally not defaulted
for AUI type devices. To enable the addresses you will be using for
6270s, use an alpha-keypad and follow the procedures for Device
Programming in your control panel Programming Guide.